As we all know, in the pipeline system, the check valve is a vital component, used to control the one-way flow of fluid and prevent backflow and cross-contamination. However, determining where to install the check valve—whether it is before or after the outlet valve—may raise some questions in practice.
In fact, the correct installation location depends on several factors, including the design of the piping system, fluid characteristics, and application requirements.
It is a common practice to install a check valve before the outlet valve, and its main purpose is to ensure the stability of the valve system and the accuracy of fluid control. This configuration has the following advantages:
Protection valve:
Installing a check valve protects the outlet valve from reverse flow and hydraulic shock. When the fluid stops flowing, the check valve will quickly close to prevent reverse flow and reduce damage to the valve caused by pressure fluctuations.
Maintain Fluid Pressure:
In some applications that need to maintain a stable fluid pressure, installing a check valve before the outlet valve can effectively control the fluid pressure and avoid pressure drop caused by reverse flow.
Avoid contamination:
In applications where fluid purity needs to be maintained, installing a check valve before the outlet valve can effectively prevent backflow and prevent fluid contamination or mixing.
Installing a check valve after the outlet valve is also an option, especially for certain industrial applications. This configuration also has its rationale:
To prevent pressure loss:
Installing a check valve after the outlet valve can avoid introducing additional pressure losses during normal flow. This is important for some applications requiring larger flow rates and lower pressure losses.
Fluid control:
For some applications that require more precise fluid control, installing a check valve after the outlet valve can better control the flow direction and speed of the fluid.
Reduce maintenance costs:
In some cases, installing a check valve after the outlet valve may reduce maintenance costs because the check valve does not close and open as frequently when fluid stops flowing.
When we decide to install the check valve before or after the outlet valve, we need to consider a variety of factors, including fluid characteristics, piping system design, application requirements, etc.
Whether you choose to install the check valve before or after the outlet valve, there are applicable scenarios and advantages. The key is to ensure that the installation location meets the flow control and stability needs of the fluid system to ensure the performance and safety of the piping system.